- Research Areas
- Physics of Energy Harvesting
- Materials Physics and Engineering
- Radio & Atmospheric Sciences
- Time and Frequency Standards
- Time & Frequency Standards
- QHR Standards
- JVS & DC Current, Voltage & Resistance Standards
- DC High Voltage Standards
- AC Power and Energy Standards
- AC High Current & High Voltage Standards
- LF & HF Impedance Standards
- LF & HF Voltage, Current & RF Power Standards
- RF Attenuation & Impedance Standards
- Magnetic Standards
- Bio-Medical Standards
- Electronics & Instrumentation
- Apex Level Standards and Industrial Metrology
- Quantum Phenomena and Applications
- Support Units
- Institutional Repository
- Knowledge Resource Center
- Tenders
- Login
Calibration Charge: LF & HF Voltage, Current and RF Power
Wed, 09/28/2011 - 12:44 — admin
|
Calibration Charges: LF, HF Voltage, Current & RF Power |
|||||||||||
|
AC Voltage, AC Current, Frequency, AC-DC Voltage Transfer Difference, AC-DC Current Transfer Difference, RF Voltage, Level & Frequency, Effective Efficiency, Calibration Factor, RF Power, Voltage Amplitude & Frequency, Amplitude Modulation & Frequency Modulation, Oscilloscope and AC-DC Voltage & Force |
|||||||||||
|
Sl. No. |
Parameter |
Item Type / Group |
Item Name |
Alias Name |
Range |
No. of Points for Calibration / Procedure No. |
Limitation / Condition |
Charges per Item Rs. |
Additional Charges Rs. |
Description for Additional Charges |
Remarks, if any |
|
1 |
AC Voltage & Current |
Multimeter |
Multimeter 7½ digit and above |
Digital Multimeter |
1mV to 1000 V 1mA to 20A |
3 Frequencies |
|
77000 |
24000 |
For each additional frequency |
|
|
2 |
AC Voltage & Current |
Calibrator |
Voltage & Current Calibrator |
Multifunction / Multi Product Calibrator |
1mV to 1000 V 1mA to 2A |
3 Frequencies |
|
77000 |
24000 |
For each additional frequency |
|
|
3 |
AC Voltage |
Reference Source |
AC Reference Source |
|
|
1 Frequency |
|
10900 |
10900 |
For each additional frequency |
|
|
4 |
AC Current |
Transconductance Amplifier |
Transconductance Amplifier |
AC Current Source |
Up to 20A |
1 Frequency |
|
24000 |
24000 |
For each additional frequency |
|
|
5 |
Frequency |
Frequency Counter |
Frequency Counter |
Frequency meter |
|
Frequency / Period |
Stability >1.0E-8 |
22000 |
|
|
For 'Basic Oscillator' calibration of this counter, see "Time & Freqency" Parameter |
|
6 |
Frequency |
Frequency Counter |
Universal Counter |
|
|
Frequency / Period & Time Interval |
|
31000 |
|
|
|
|
7 |
AC-DC Voltage Transfer Difference |
Potentiometer |
Micropotentiometer |
Low Voltage TVC |
|
1 Frequency |
|
9000 |
9000 |
For each additional frequency |
|
|
8 |
AC-DC Voltage Transfer Difference |
Thermal Converter |
Thermal Voltage Converter |
|
|
1 Frequency |
|
9000 |
9000 |
For each additional frequency |
|
|
9 |
AC-DC Voltage Transfer Difference |
Thermal Transfer Standard |
Thermal Transfer Standard |
|
250 mV to 1000 V |
1 Frequency |
|
68000 |
60100 |
For each additional frequency |
|
|
10 |
AC-DC Voltage Transfer Difference |
Thermal Transfer Standard |
Thermal Transfer Standard |
|
2mV to 1000 V |
1 Frequency |
|
88000 |
77000 |
For each additional frequency |
|
|
11 |
AC-DC Current Transfer Difference |
Shunt |
Current Shunt |
|
|
1 Frequency |
|
9000 |
9000 |
For each additional frequency |
|
|
12 |
RF Voltage |
Voltmeter |
Selective Microvoltmeter |
Level Meter |
Up to 1000 MHz |
6 Frequencies with One Input Impedance |
|
48000 |
13000 |
For each additional input impedence |
|
|
13 |
RF Voltage |
Voltmeter |
RF Millivoltmeter |
|
Up to 1000 MHz |
6 Frequencies per probe |
|
48000 |
13000 |
For each additional probe |
|
|
14 |
RF Power & Frequency |
Signal Generator |
Synthesizer |
Sweep Oscillator |
|
Power Level, Time Base Accuracy & Frequency Response at 5 frequency points |
|
48000 |
5000 |
For each additional frequency |
|
|
15 |
RF Power & Frequency |
Spectrum Analyser |
Spectrum Analyser |
Wave Analyser |
|
Power Level, Time Base Accuracy & Frequency Response at 5 frequency points |
|
48000 |
5000 |
For each additional frequency |
|
|
16 |
Effective Efficiency / Calibration Factor / RF Power |
Power Meter |
RF Power Meter with Sensor |
|
Up to 30 Watts |
3 Frequencies and one Sensor (Effective Efficiency/ Calibration Factor/ RF Power) |
|
16500 |
5000 |
For each additional frequency |
(For VSWR, separate charges under VSWR/reflection coefficient parameter) |
|
17 |
Effective Efficiency / Calibration Factor |
Coaxial Thermistor Mount |
Coaxial Thermistor Mount |
Power Mount |
|
1 Frequency |
|
33000 |
10900 |
For each additional frequency |
(For VSWR, separate charges under VSWR/reflection coefficient parameter) |
|
18 |
Effective Efficiency / Calibration Factor |
RF Power Transfer Standard |
RF Power Transfer Standard |
|
|
1 Frequency |
|
10000 |
9300 |
For each additional frequency |
(For VSWR, separate charges under VSWR/reflection coefficient parameter) |
|
19 |
AC Voltage & Frequency |
Oscilloscope Calibrator |
Oscilloscope Calibrator |
|
|
Time Mark, Voltage Amplitude, Frequency & Pulse Amplitude |
|
55000 |
|
|
|
|
20 |
Voltage Amplitude & Frequency |
Function Generator |
Waveform Generator |
|
|
Voltage & Frequency at 5 frequency points |
|
48000 |
5000 |
For each additional frequency |
|
|
21 |
Amplitude Modulation & Frequency Modulation |
Modulation Analyser |
Modulation Meter |
|
|
Modulation Index & Carrier Deviation at 5 frequency points |
|
48000 |
5000 |
For each additional frequency |
|
|
22 |
AC-DC Voltage & Force |
Amplifier with Load cell |
Dynamic Strain Meter |
|
0-5 V and upto 100 kN |
One channel in one load cell |
|
42000 |
38000 |
For each additional channel / load cell |
Includes Rs 22,000/- for Force Standard (D5.05) |