A Premier Research Laboratory in India in the Field of Physical Sciences
IST : 
Calibration Charge: LF & HF Voltage, Current and RF Power

Calibration Charges: LF, HF Voltage, Current & RF Power

AC Voltage, AC Current, Frequency, AC-DC Voltage Transfer Difference, AC-DC Current Transfer Difference, RF Voltage, Level & Frequency, Effective Efficiency, Calibration Factor, RF Power, Voltage Amplitude & Frequency, Amplitude Modulation & Frequency Modulation, Oscilloscope and AC-DC Voltage & Force

Sl. No.

Parameter

Item Type / Group

Item Name

Alias Name

Range

No. of Points for Calibration / Procedure No.

Limitation / Condition

Charges per Item Rs.

Additional Charges Rs.

Description for Additional Charges

Remarks, if any

1

AC Voltage & Current

Multimeter

Multimeter 7½ digit and above

Digital Multimeter

1mV to 1000 V 1mA to 20A

3 Frequencies

 

77000

24000

For each additional  frequency

 

2

AC Voltage & Current

Calibrator

Voltage & Current Calibrator

Multifunction / Multi Product Calibrator

1mV to 1000 V 1mA to 2A

 3 Frequencies

 

77000

24000

For each additional  frequency

 

3

AC Voltage

Reference Source

AC Reference Source

 

 

1 Frequency

 

10900

10900

For each additional  frequency

 

4

AC Current

Transconductance Amplifier

Transconductance Amplifier

AC Current Source

Up to 20A

1 Frequency

 

24000

24000

For each additional  frequency

 

5

Frequency

Frequency Counter

Frequency Counter

Frequency meter

 

Frequency / Period

Stability >1.0E-8

22000

 

 

For 'Basic Oscillator' calibration of this counter, see "Time & Freqency" Parameter

6

Frequency

Frequency  Counter

Universal Counter

 

 

Frequency / Period & Time Interval

 

31000

 

 

 

7

AC-DC Voltage Transfer Difference

Potentiometer

Micropotentiometer

Low Voltage TVC

 

1 Frequency

 

9000

9000

For each additional  frequency

 

8

AC-DC Voltage Transfer Difference

Thermal Converter

Thermal Voltage Converter

 

 

1 Frequency

 

9000

9000

For each additional  frequency

 

9

AC-DC Voltage Transfer Difference

Thermal Transfer Standard

Thermal Transfer Standard

 

250 mV to 1000 V

1 Frequency

 

68000

60100

For each additional  frequency

 

10

AC-DC Voltage Transfer Difference

Thermal Transfer Standard

Thermal Transfer Standard

 

2mV to 1000 V

1 Frequency

 

88000

77000

For each additional  frequency

 

11

AC-DC Current Transfer Difference

 Shunt

Current Shunt

 

 

1 Frequency

 

9000

9000

For each additional  frequency

 

12

RF Voltage

Voltmeter

Selective Microvoltmeter

Level Meter

Up to 1000 MHz

6 Frequencies with One Input Impedance

 

48000

13000

For each additional  input impedence

 

13

RF Voltage

Voltmeter

RF Millivoltmeter

 

Up to 1000 MHz

6 Frequencies per probe

 

48000

13000

For each additional probe

 

14

  RF Power & Frequency

Signal Generator

Synthesizer

Sweep Oscillator

 

Power Level, Time Base Accuracy & Frequency Response at 5 frequency points

 

48000

5000

For each additional  frequency  

 

15

 RF Power & Frequency

Spectrum Analyser

Spectrum Analyser

Wave Analyser

 

Power Level, Time Base Accuracy & Frequency Response at 5 frequency points

 

48000

5000

For each additional  frequency  

 

16

Effective Efficiency / Calibration Factor / RF Power

Power Meter

RF Power Meter with  Sensor

 

Up to 30 Watts

3 Frequencies and one Sensor (Effective Efficiency/ Calibration Factor/ RF Power)

 

16500

5000

For each additional  frequency  

 (For VSWR, separate charges under VSWR/reflection coefficient parameter)

17

Effective Efficiency / Calibration Factor

Coaxial Thermistor Mount

Coaxial Thermistor Mount

Power Mount

 

1 Frequency 

 

33000

10900

For each additional  frequency

 (For VSWR, separate charges under VSWR/reflection coefficient parameter)

18

Effective Efficiency / Calibration Factor

RF Power Transfer Standard

RF Power Transfer Standard

 

 

1 Frequency 

 

10000

9300

For each additional  frequency

 (For VSWR, separate charges under VSWR/reflection coefficient parameter)

19

AC Voltage & Frequency

Oscilloscope Calibrator

Oscilloscope Calibrator

 

 

Time Mark, Voltage Amplitude, Frequency & Pulse Amplitude

 

55000

 

 

 

20

Voltage Amplitude & Frequency

Function Generator

Waveform Generator

 

 

Voltage & Frequency at 5 frequency points

 

48000

5000

For each additional  frequency  

 

21

 Amplitude Modulation & Frequency Modulation

Modulation Analyser

Modulation Meter

 

 

Modulation Index & Carrier Deviation at 5 frequency points

 

48000

5000

For each additional  frequency  

 

22

AC-DC Voltage & Force

Amplifier with Load cell

Dynamic Strain Meter

 

0-5 V and upto 100 kN

One channel in one load cell

 

42000

38000

For each additional channel / load cell

Includes Rs 22,000/- for Force Standard (D5.05)